29 (f) (1) (i)) (as measured at the leading edge of the stair tread to the top surface of the rail). The employer must ensure guardrail systems meet the following requirements: ( 1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107. A handrail and a railing as applied to fixed industrial stairs have two different meanings. 1-2007, Safety Requirements for Workplace Walking/Working Surfaces and Their Access; Workplace Floor, Wall and Roof Openings; Stairs and Guardrail Systems. On outside plaza, patio, and garden areas, alternate means of protection are acceptable if the same degree of safety is provided. Paragraph (g)(4)(xiv) requires that guardrail systems using manila, plastic or synthetic rope as rails be inspected by a competent person as frequently as necessary to ensure that the guardrails comply with the performance criteria in final rule §1926. 1052 (c) (2) Winding and spiral stairways shall be equipped with a handrail offset sufficiently to prevent walking on those portions of the stairways where the tread width is less than 6 inches (15 cm). Install guardrail systems along all open sides and ends of platforms. The Occupational Safety and Health Administration (OSHA) standard at 29 CFR 1926. 91-596, encourages states to develop and operate, under OSHA guidance, their own job safety and health plans. Cal OSHA has a force requirement of 20 pounds per linear foot along the entire rail system. Refrigerated trucks are 50 to 60 inches in bed height, so they always will require a guardrail. It applies to classrooms with permanent and temporary floor holes and openings greater than 1 inch in its least dimension, floor drains, manholes, hatchways, ladder. Guardrail Fall Protection Criteria. Hazards are identified, as well as the controls that keep these hazards from becoming tragedies. In particular, toeboards used for falling object protection are as follows: Toe Board Height Requirements: 29 (k) (1) (ii): “have a vertical minimum height of 3. 1926. The top edge height may exceed 45 inches (114 cm). - to “one stair rail system with handrail on each open side”. 503 (a) (1) The employer shall provide a training program for each employee who might be exposed to fall hazards. That said, even docks coming in under 4 feet should utilize some sort of fall protection. There are separate standards set by OSHA for General Industry and Construction. IBC 2000 1-1/2 inch minimum. When a forklift truck is used for lifting personnel on a secured safety platform with a guardrail to. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. Finally, remember handrails must be between 30 and 38 inches as measured from the leading edge of the stair tread. You’re completely OSHA compliant for inspection at a moments notice. Keep away from the edge. 8. This ribbon of rail acts to capture impacting vehicles and to. S. 10. 451 (a) (5). OSHA publishes a final rule. Department of Labor, OSHA, Office of Construction Standards and Guidance, Room N3468, 200 Constitution Avenue, N. (3) If ramps change direction at landings, the minimum landing size shall be 60 in by 60 in (1525 mm by 1525 mm). Though the terms guardrails and handrails are often used interchangeably, they are different structures both in use and requirements. (link is external) Summary Report of 2021 MASH Virtual Roundtables. For more information, visit or call OSHA at 1-800-321-OSHA (6742), TTY 1-877-889-5627. NCHRP Roadside Hardware Replacement Analysis: User Guide. 1926. 451(g)(4). S. That being said, there are no requirements for a fall arrest system or ladder safety system for offset fixed ladders 24 feet and under in height so long as the ladder resting platforms at all transitions are of minimum horizontal dimensions (29 CFR § 1910. 451 (b) (3) (ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm). 500 (f) (l) (vi) provides for the utilization of types, sizes and arrangements of railing construction provided they meet the conditions established in sub-paragraph a thru d. 2. 555 (a) (1) Means for stopping the motor or engine shall be provided at the operator's station. The stairway is over 88 inches in width. 1052 (c) (3) The height of stairrails shall be as follows: 1926. Here’s a quick overview. 48 (a) (2) An elevated walkway with guardrail or equivalent means of protection shall be provided where employees cross over moving conveyors, and suitable guarding shall be provided when employees pass under moving conveyors. OSHA 1910. 500-1926. Dear Mr. OSHA requirements are set by statute, standards and regulations. Maximum riser height of 9. 1917. State Plan Standards. 1431 (b) (2) (i)1915. 23(e)(6) states: "All handrails and railings shall be provided with a clearance of not less than 3 inches between the handrail or. OSHA Requirements. Guardrail systems and their use shall comply with the following provisions: – 1926. need to be provided for(The requirements to have guardrail systems with toeboards for falling object and overhead protection on platforms and landings are set forth in subpart M of this part. 23 (e) (3) (iii), installations, posts and top and intermediate rails are to be of 2-inch by 2-inch by 3/8-inch angles or other metal shapes of equivalent bending strength with posts spaced not more than 8 feet on centers. These updated standards finally provided clarification for service pits, specifying that guardrails are not required around service pits less than 10 feet in depth. The job-built guardrail systems were evaluated to determine whether they complied with OSHA regulation 29 CFR 1926. OSHA requirements for guardrails are also quite stringent. If the guardrail is unable to bear the minimum structural load, it could break due to the applied forces, resulting in a tragic accident. OSHA states that guardrail must reach a height of 42 inches, plus or minus 3 inches, above the walking-working surface and withstand a force of 200 pounds at any point in a downward or outward direction. 451 (b) (4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). According to the IBC code, guard rails are required when there is a difference of 30 inches or greater between two upper and lower surfaces. Guardrail Requirements vs. 29(f)(1)(ii)(B)) and the handrail must be 30 to. The OSHA requirements state that guardrails should be able to resist at least 200 pounds of pressure applied directly to the structure. Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate. The agency has received numerous questions asking when handrails are required, and about the height requirements for handrails on stairs and stair rail systems. 71 (d) (2) All vertical and horizontal members shall be fastened together with a coupler or locking device which will form a positive connection. Thickness requirements: OSHA standard 1926. e. This is why roof safety rails are so important. For safety- and health-related assistance, employers and employees may contact the nearest Cal/OSHA Consultation . The OSHA non-mandatory guidelines do not provide suggested hardware for fastening the guardrails to the ground. 1926. For employers who have been doing their best to keep. 1053(a)(1)] Additional Information: 29 CFR 1926 Subpart X, Ladders. If the handrail isn’t circular, the perimeter dimension should not be less than 4 inches and mustn’t be greater than 6. 28 and 1910. The employer must ensure: 1910. Re: Stair rail and hand rail heights; §1926. Different requirements for children show a maximum height of 28″ with a minimum clearance of 9″ between the adult rail and the childrens’ rail, which is only a recommendation and not a requirement. Mr. We will now. (a) Stairways shall have handrails or stair railings on each side, and every stairway required to be more than 88 inches in width shall be provided with not less than one intermediate stair railing for each 88 inches of required. 29 repeats itself a lot and it can be a little confusing to sort through. 1-2007, Safety. Federal OSHA says the height of the top rail can be between 39 and 45 inches, while Cal-OSHA does not permit top rails to be so low. TO: ALL AREA DIRECTORS Paragraph 1926. Kevin Rauchut NVR, Inc. Use pedestrian walkways, or stay to one side of the equipment aisle. Standards Institute, Standard A1264. 501(b)(13), workers engaged in residential construction six (6) feet or more above lower levels must be protected by conventional fall protection (i. Safety Standards for Scaffolds. There is a 3-inch variance that is allowed in either direction. Guardrail systems used at hoist areas: A removableAmerica's Safest Companies. Handrail Requirements. Therefore let us recap on the residential stair code requirements: Minimum 36 inch clear width for stairway. The Occupational Safety and Health Administrations, Safety and Health Regulations for Construction, specifically 1926. Minimum 6′-8″ headroom height clearance for stairway. Using these definitions, therefore, OSHA concludes that a skylight should be regarded as a hatchway, i. M-606-1 Midwest Guardrail System (MGS) Type 3 W-Beam 31 Inches (Placement, installation, materials, and specifications). The scaffolding fall protection requirements are located in §1926. 1926. Under §1910. 451 (a) (5). This 200 pound load test is designed to stop an employee from. "The employer must ensure each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1. The Occupational Safety and Health Administration requires that employers provide fall protection for employees working at heights over 4 feet. 451(g)(4). The Ontario Building Code | Handrails 3. C. OSHA requirements are set by statute, standards and regulations. Advanced Notice of Proposed Rules 64:38077-38086, (July 14, 1999). [29 CFR 1926. (3) For structural steel railings: posts, top rails, and. 452, . While guardrails and handrails sound similar and perform the same general function — fall protection — the actual definition and code requirements for each differ considerably. (c) Safety net systems. 3. 82 cm ±7. e. Thank you for your inquiry. OSHA 1910. Definitions . 29 and their roof guardrail requirements, we've identified at least 4 areas of major concern for rooftop safety that would require a safety rail for roof system. Reg. Minimum tread depth of 9. 1915. 1917. OSHA also states that the guardrails must be between 39 and 45 inches tall. The employer must ensure guardrail systems meet the following requirements: 1910. The fall protection requirements for residential construction are set out in Subpart M at 29 CFR 1926. A stair rail or stair guard is a safety railing or barrier located along the open side(s) of a stairway. 1926. § 214. Where the guardrail requirements of subsections (a) and (b) are impracticable due to machinery requirements or work. Equivalent means. OSHA Standards. 46 m 2) for each person. Slope between 30° and 50° from the horizontal. Not understanding how they are different can lead to being out of compliance and possible heavy fines. Implement safe work practices to reduce the possibility of falls. 21 - Scope and definitions. A handrail and a wall or other surface adjacent to the handrail shall be free of any sharp or abrasive elements. Pursuant to §1910. (2) If the required width of a ramp or flight of stairs is more than 2 200 mm, one or more intermediate handrails continuous between landings shall be provided, and located. Mid rail height of 21 inches. Further, OSHA standard 1910. Guardrails: Handrails: OSHA: Height: . 26 (b) (1) Dockboards put into initial service on or after January 17, 2017 are designed, constructed, and maintained to prevent transfer vehicles from running off the dockboard edge; 1910. 01 inches is required for the edges. Maximum 12′-7″ vertical height (rise) for a flight of stairs. Any vertical intermediate members (EX. ) Floor opening – An opening 12 inches or more in its least dimension in any floor, roof or platform, through which a person, material or tool. 23(e)(1)] The intermediate (middle) rail should be located in the middle of the upright creating equal space between the floor and the top. Department of Labor, OSHA, Office of Construction Standards and Guidance. Employers should train workers to: Check to see that a guardrail system is in place before working on the scissor lift. Depending on the type of scaffold, each employee more than 10 feet above a lower level must be protected from falling either by a personal fall arrest system, a. A safety handrail provides stability with a handhold on a platform, walkway, stairway or step. 3 OSHA standards permit fall arrest systems to be anchored to scissor lifts as long as the anchorage requirements in §1926. Minimum width of 22”. Use internal couplings, Type 18-7, to maintain continuity. Where the guardrail requirements of subsections (a) and (b) are impracticable due to machinery requirements or work. 451(g). Code requires guardrail in residential structures be a minimum of 36 inches. 6. This appendix serves as a non-mandatory guideline to assist employers in complying with these requirements. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. Office listed on the back cover of this guide. [29 CFR 1926. 28; 1910. 2. Here are some basic pieces of information to bear in mind when constructing a handrail to comply with OSHA Standards. Kee Gate's spring-loaded self-closing hinge ensures that the gate will automatically close, maintaining a constant safety barrier between the user and the hazard. 502(d)(21) OSHA requirements are set by statute, standards and regulations. Handrail must be continuous. 502(c)(2). Standard Interpretations are letters or memos written in response to public inquiries or field office inquiries regarding how some aspect of or terminology in an OSHA standard or regulation is to be interpreted and enforced by the Agency. An opening between 3½ and 9 inches should be avoided because of the danger of entrapment. The agency’s standard on walking-working surfaces for general industry (1910 Subpart D) was developed to help prevent dangerous falls from height or slips and trips on the same level (working surface). Our parapet guardrail is designed to exceed OSHA requirements to ensure you and your employees are safe when working on the roof. With an extended catch platform preventing employees from falling to the ground, the catch platform would have been the only lower level, and (other than the. OSHA 1910. S. American National Standards Institute (ANSI) ANSI/ASSE A1264. A strength to withstand at least the minimum requirement of 200 pounds top rail pressure (§1910. Minimum tread depth of 9. The maximum and minimum cross-sectional dimension should be 2. S. SUBJECT: 1926. 8-2019 standard). Spiral stairs must meet the vertical clearance requirements. 502 (b) (1): Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1. Docket S-775 Safety Standards for Steel Erection (proposed January 26, 1988, 53 FR 2048, final rule published January 18, 2001 66 FR 5196). OSHA is therefore proposing to clarify that the top rail of stair rail systems installed prior to January 17, 2017, can serve as a handrail if that top rail is 30 to 38 inches in height and meets the other handrail requirements of paragraph (f). are good for high entry ways and cathedral ceiling areas of residential homes. Use only ladders that comply with OSHA design standards. The following definitions apply in this subpart: Alternating tread-type stair means a type of. Double-cleat ladder means a ladder similar in construction to a single-cleat ladder, but with a center rail to allow simultaneous two-way traffic for employees ascending or descending. All workers reaching more than 10 inches below the level of the walking or working surface on which they are working must be protected by a guardrail system, safety net system, or personalOn November 18, 2016, OSHA published a final rule on Walking-Working Surfaces and Personal Protective Equipment (Fall Protection Systems) in the Federal Register ( 81 FR 82494 ). 1910. Common shapes are flat, rounded edge, and tubular in horizontal railings, whereas tetraform spear-headed or ball. 555 (a) General requirements. Top rails capable of withstanding 200 pounds of. Toeboards need to be around 3. 501 ), any worker constructing a leading edge 6 feet or more above a lower level “must be protected by guardrail systems, safety net systems, or personal fall arrest systems. 23) do not directly address the spacing of posts in between sections of a freestanding modular guardrail system. Requirements for suspension scaffold fall protection systems are contained in § 1910. Be aware of the wide rear swing radius. 29 (b) (1): To meet OSHA’s guardrail height requirements, the top rail needs to be 42 inches plus or minus 3 inches above the walking-working surface. OSHA eTool. 453, and . Zarletti: Thank you for your letter of June 18, concerning the allowable tolerance for the height of guardrails as specified at 29 CFR 1926. These include: The top edge height of top rails, or equivalent guardrail system. Similarly, OSHA's general industry standards related to guardrail systems (Subpart D Walking-Working Surfaces, specifically 29 CFR 1910. Maintenance of rooftop solar panels falls under general industry standards. Do the OSHA Construction standards apply to me? The standards apply to: All contractors who enter into contracts which are for construction, alteration, and/or repair, including painting and decorating. The CSA Standard Z797-18 Code of practice for access scaffold also provides minimum load bearing and height requirements for guardrails and toe boards. OSHA's guardrail height requirements include a variance of plus or minus 3 inches. There are 29 OSHA-approved State Plans operating state-wide occupational safety and health programs. OSHA standard 1926. 502(d) and the requirements of the scaffold standard are met. [29 CFR 1926. We apologize for the long delay in providing this response. The guardrails provided here are 1-1/4” thick. OSHA Standard. This elevated work area is still clearly a hazardous area and you. 5. 29 – Fall protection systems and falling object protection-criteria and practices. Panels made of materials conforming to the requirements in Table. 1910. . Effective guardrail and safety railing installation to prevent falls must meet the standards set by OSHA. 1052(c)(7) Dear Mr. Answer. 26. 25 (b) (1) Handrails, stair rail systems, and guardrail systems are provided in accordance with § 1910. Re: Stair rail and hand rail heights; §1926. This letter constitutes OSHA's interpretation of the requirements discussed. [Note: for this section, the criteria and practices requirements for guardrail systems on scaffolds are contained in 29 CFR part 1926, Subpart L or 29 CFR 1915. 30″ to 38″. Purpose of a Guardrail . Guardrail systems must be capable of withstanding, without failure, a force of at least 200 pounds applied in a downward or outward direction at any point within two inches of the. 502(k) and training that meets the requirements of 29 CFR. A guardrail is typically required for stairs with 4-or-more risers, or for a deck or balcony with 30 inches above grade. Section 18(b) of The Occupational Safety and Health Act of 1970, P. This threshold differs from 29. 1052(c)(7) Dear Mr. Surface requirements: OSHA standard 1926. Minimum tread depth of 9. [Docket ID–OSHA–2020–0009] RIN 1218–AD28 Walking-Working Surfaces AGENCY: Occupational Safety and Health Administration (OSHA), Labor. . 6 series), a worker need only be protected from falling by a properly designed and. Top rail and midrail dimensions: Must be at least 0. 23 & 1926. 5 inches (24 cm); ( 3) Have a minimum tread depth of 9. Railing height from tread surface at the riser face shall be 33±3 inches (83. Occupational Safety and Health Administration 200 Constitution Ave NWThe AASHTO Manual for Assessing Safety Hardware (MASH). 760 (c) (2) Access to a CDZ shall be limited to only those employees engaged in leading edge work. A guardrail system also provides a safety barrier for other internal and external exposure spots of a building or site. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. 29 (k) includes standards for “protection from falling objects”. 1910. The employer must provide safe access to and from all workGuide to cable railings or wire rope guardrails: This article describes and includes illustrations of cable or wire rope railings or guardrails used along decks, balconies, walkways and stairways. Plastic ladders: ANSI A14. Presuming your guardrail system meets the requirements of §1926. This Safety and Health Information Bulletin is not a standard or regulation, and it creates no new legal obligations. 1910. This regulation states that, “Guardrail systems. 450, . ( 4) Have a minimum width of 22 inches (56 cm) between vertical. The short answer is usually, yes. Maximum mesh size must not exceed 6 inches by 6 inches. 5 inches (9 cm) as measured from the top edge of the toeboard to the level of the. This means you cannot place machinery or other equipment in the space around an electrical panel without making sure that it meets the NEC working clearance requirements. This is the first OSHA requirement to be aware of. A catwalk handrail or guardrail system is required for any catwalks higher than 4′ above a lower level. Occupational Safety and Health Administration 200 Constitution Ave NW Washington, DC 20210 1-800-321-OSHA 1-800-321-6742. 503(a) and (c). Handrail Standards Guardrail Handrail standards can be manufacured in tubular or solid materials with varying outside diameters, tube wall thickness, ball sizes, ball types in a multiple of material grades in Mild Steel, StainlessOSHA; Standards; Enforcement; Topics; Media Center; Contact Us; U. 1917. Maximum riser height of 9. 29(g)(4)), have an acceptable guardrail system (29 CFR § 1910. Under 29 CFR 1926. Safety Standards for Scaffolds. ( 4) Have a minimum width of 22 inches (56 cm) between vertical. Be sure you have. The space between the inside of the handrail and the wall or any other obstruction must be at least 1-1/2”. Cal OSHA has a force requirement of 20 pounds per linear foot along the entire rail system. Will the Guardrail Meet Loading Dock Railing Requirements? OSHA details the requirements for guardrails in more detail since the 2017 update. 502 - OSHA's new fall protection standards for construction will prohibit use of safety belts with side dee rings as part of a personal fall arrest system - 09/25/1995 1926. 1910. not specified. Prevent water from pooling and damaging your roof by using a lightweight PVC counterweight to give your team all the protection they. This regulation states that, “Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5. 1. The OSHA requirements state that guardrails should be able to resist at least 200 pounds of pressure applied directly to the. Open-sided dock areas 4 feet or more above adjacent floor or ground level where there is the danger of employee falling shall be guarded by a standard railing or the equivalent. 23(c)(1) states that “e very open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides. To meet OSHA’s guardrail height requirements, the top rail needs to be 42 inches plus or minus 3 inches above the walking-working surface. So, that height can be anywhere from 39 inches to 45 inches. Re: Guardrail requirements for two point suspension scaffolds Dear Mr. (1) For wood railings: Wood components shall be minimum 1500 lb-ft/in2 fiber (stress grade) construction grade lumber; (2) For pipe railings: posts, top rails, and intermediate railings shall be at least one and one-half inches nominal. 451 (g) (1), each employee on a scaffold more than 10-feet above a lower level must be protected from falling to that lower level (also note American National Safety Institute/American Society of Safety Professionals (ANSI/ASSP) – Scaffolding Safety Requirements A10. Last updated: Tuesday,. The fact that residential construction has gone unregulated and unenforced. I. [29 CFR 1926. OSHA states that guardrail must reach a height of 42 inches, plus or minus 3 inches, above the walking-working surface and withstand a force of 200 pounds at any. GUARDRAIL 101. OSHA Fall Protection Requirements. This includes the top of retaining walls over 4 feet in height. Double-cleat ladder means a ladder similar in construction to a single-cleat ladder, but with a center rail to allow simultaneous two-way traffic for employees ascending or descending. 452(w)(6)(ii)). 452(x)(9) 1926. A guardrail is shown by the red arrows in our photo at left. 4, and the lowest, a safety net that meets the requirements of section 26. The top rail rail must be able to withstand 200 pounds of force in the downward and outward directions. 1053(a)(11). OSHA standard 1926. 4. 1052(c)(6) and 1926. , guardrail systems, safety net systems, or personal fall arrest systems) or alternative fall protection measures allowed under 1926. 1910. Here is a list of important OSHA standards for work platforms that you may not be aware of. 29(b) and its subparts. In addition to paragraph (b) of this section, the employer must ensure standard stairs: ( 1) Are installed at angles between 30 to 50 degrees from the horizontal; ( 2) Have a maximum riser height of 9. 112(c)(1) on both sides and that are not less than 30 inches (76. If the railing dips below 39 inches, due to the force, the railing is not OSHA compliant. Stand clear of forklifts in operation. balusters) can be a maximum of 19 inches apart. Phone: Fax: Buy guardrail netting for mid-rail and toe board fall protection, in addition to overhead protection against debris. 1910. 450(b) 1926. 29 repeats itself a lot and it can be a little confusing to sort through. OSHA requirements are set by statute, standards, and regulations. Employee Work Areas Common use circulation paths must be accessible in work areas 1,000 sq. 500 (f) (1) (vi) provides the specification criteria for a standard railing exception as follows: (vi) Other types, sizes, and arrangements of railing construction are acceptable, provided they meet the following conditions: (a) A smooth-surfaced top rail at a height above floor, platform, runway, or ramp level of approximately 42. 30. SUMMARY: OSHA is proposing changes to the Walking-Working Surfaces standards to clarify which handrail and stair rail system requirements apply to new stair rail. 1431 (b) (2) Exceptions: A personnel platform is not required for hoisting employees: 1926. 213/91, the highest being a travel restraint system that meets the requirements of section 26. Any vertical intermediate members (EX. 3) the top must not fail and may deflect to a point no lower than 39 inches above the floor when a 200 pound load is imposed on it in a downward or outward. Mr. Handrail must be continuous. In addition, Section 5 (a) (1) of the Occupational Safety and Health (OSH) Act, often referred to as the General Duty Clause, requires employers to "furnish to each of his employees employment and a place of employment which are free from recognized. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. 36″ to 38″ — may also serve as guard. Here are OSHA’s requirements for guardrail height: The top of the rail system must be 42 inches (±3 in. Occupational Safety and Health Standards; Subpart: 1910 Subpart D; Subpart Title: Walking-Working Surfaces; Standard Number: 1910 Subpart D Title:. 23(e)(5)(iii), states in part: "The length of brackets shall be such as will give a clearance between handrail and wall or any projection thereon of at least 3 inches. Scaffolding. Loads are unfactored - please contact our technical department should safety factored loading be required. 28 and 1910. The following requirements apply to all stairways as indicated: (1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with: (A) At least one handrail; and (B) A stair rail consisting of a top rail and mid-rail along each unprotected side or edge. It covers all walking-working surfaces unless specifically excluded by an individual section of this subpart. 23). 2. Access. Maximum 12′-7″ vertical height (rise) for a flight of stairs. Guardrail systems and their use shall comply with the following provisions: 1926. The IBC code for structural design has some very specific requirements for deck stairs: Stair rails on decks should be between 34 inches and 38 inches high, measured vertically from the nose of the tread to the top of the rail. Here is a summary to make it easy for you: The top rail must be 42 inches in height, give or take 3 inches. OSHA standard 1926. 29 Fall Protection Systems and Falling Object Protection-Criteria and. 451(a)(5) is acceptable provided it meets the following guidelines: OSHA requirements are set by statute, standards and regulations. Falls from heights and on the same level (a working surface) are among the leading causes of serious work-related injuries and deaths. * The CPSC recommends that. 1910. Compliance requirements for the use of U-bolt-type cable clamps in horizontal lifelines. Only stand on the work platform; never stand on the guardrails. 20210. 13(c)]OSHA requirements are set by statute, standards and regulations. OSHA requirements are set by statute, standards and regulations. 3. Load Requirement: It should be to hold a load from a 200-pound weight that is. 25 inches. 501(b)(13), workers engaged in residential construction six (6) feet or more above lower levels must be protected by conventional fall protection (in other words, guardrail systems, safety net systems, or personal fall arrest systems) or other. Mid rail height of 21 inches. 75(g) Catwalks on stiles of marine railways shall be no less than 20 inches wide and shall have on at least one side a guardrail and midrail meeting the requirements of § 1915.